Customization: | Available |
---|---|
Type: | Lithium Metal Battery |
Cathode Material: | LFP |
Suppliers with verified business licenses
Model | BOS-G |
Battery Modules | 3-12 |
Cell Chemistry | LiFePO4 |
Module Energy (kWh) | 5.12 |
Module Voltage (V) | 51.2 |
Module Capacity (Ah) | 100 |
Charge / Discharge Current (A) | Recommend: 50 ANominal: 100 APeak: 125 A (2 mins, 25°C) |
Operating Temperature (°C) | Charge: 0 ~ 55°CDischarge: -20 ~ 55°C |
Storage Temperature (°C) | 0 ~ 35°C |
Humidity | 5% - 85% RH |
Altitude | ≤ 2000 m |
Cycle Life | ≥6000 (25±2°C, 0.5C/0.5C, 70%EOL) |
Recommended DoD | 90% |
Status Indicator | Yellow: Battery High Voltage Power OnRed: Battery System Alarm |
Communication Port | CAN2.0 / RS485 |
Installation | Rack-Mounted |
IP Rating | IP20 |
System Dimensions (W × D × H, mm) | 530 × 602 × 1629 (up to BOS-G45)530 × 602 × 2187 (BOS-G50 & above) |
System Weight (kg) | 388 (typical) → 562 (BOS-G60) |
Warranty | 10 years |
Certification | CE / IEC62619 / VDE2510-50 / UL1973 / UL9540A / UN38.3 |
Q1: Do Purebus energy systems comply with international electrical and safety standards?
A1: Yes. All systems meet relevant IEC/CE/UN38.3 safety and EMC standards. Components undergo extensive testing for electrical protection, fire safety, and environmental durability (e.g., IP54/IP66 rated enclosures).
Q2: Can you provide customized configurations (e.g., capacity, voltage, communication)?
A2: Yes. Custom options include battery capacity (up to 280Ah/module), nominal voltage (LV 51.2V or HV 135-750V), and communication protocols (CAN, RS485, Wi-Fi, Ethernet). Both modular and rack-mounted systems are available.
Q3: What is the lead time for delivery?
A3: Standard products can be shipped within 7-10 working days. For customized models or large quantities, lead time is typically 20-30 days. Expedited orders and scheduled production are available upon request.
Q4: Do you support third-party inspections?
A4: Yes. Purebus welcomes third-party inspections from SGS, TUV, or client-assigned agents. Full test reports and compliance certificates are provided before shipment.
Q5: Are systems compatible with other inverter brands?
A5: Yes. Energy storage systems support open protocols (CAN/RS485) and can be integrated with a wide range of inverter brands. Configuration tools and wiring diagrams are provided for seamless setup.